 Plastic film blowing machine

 

VSD applied in platic film blowing machine


1, Load feature
  
  There are two parts on plastic film blowing machine can get energy saving:
  (1)  Power driven system, most of this part will install an additional frequency inverter, which make the main motor works at 30~40Hz to get energy saving;
. (2)  Heating system, most of this part will install an electromagnetic heater to get energy saving.

2,  Requests for frequency inverters (VSD)
  (1)  Output high torque at low frequency.
  (2)  High speed control accuracy. (to avoid the raised grain occurs on the film).

3, Instruction for commissioning
(1)  Pictures of plastic film blowing machine    

(2)  Parameters setting list (take 15Kw, 5.5kW motor as example)

No.

Function codes

Default

Setting value

Explanation

1

F00.01

0

1

Start / stop by external   signal

15kW main motor

2

F00.06

10

10

The motor speed is adjusted   by keypad potentiometer.

3

F00.12

Model depend

15s

Acceleration time   (adjustable)

4

F00.13

Model depend

15s

Deceleration time   (adjustable)

5

F04.01

0.0

2.0

Torque boost (adjustable)


1

F00.01

0

1

Start / stop by external   signal

5.5kW motor

2

F00.06

10

10

The motor speed is adjusted   by keypad potentiometer.

3

F00.12

Model depend

15s

Acceleration time   (adjustable)

4

F00.13

Model depend

15s

Deceleration time   (adjustable)


(3)  Typical wiring diagram


4, Notices
The temperature is always high on the site, pay attention to dust prevention and heat sink for frequency inverter.